{"id":10729,"date":"2023-11-02T12:06:00","date_gmt":"2023-11-02T11:06:00","guid":{"rendered":"https:\/\/blog.gsa-messgeraete.de\/measuring-mold-after-renovations\/"},"modified":"2025-12-05T13:26:58","modified_gmt":"2025-12-05T12:26:58","slug":"measuring-mold-after-renovations","status":"publish","type":"post","link":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/","title":{"rendered":"Measuring mold after renovations"},"content":{"rendered":"\n<p>Mold is often found after renovation work and can pose a health risk. Depending on the mold infestation and health sensitivity, allergic reactions or infections can be triggered. The formation should therefore be treated professionally without delay. In order to localize the spread and concentration, it is advisable to take samples with the <strong>GSA measuring devices SG5200<\/strong> to measure the mould.   <\/p>\n\n\n\n<!--more-->\n\n\n\n<h2 class=\"wp-block-heading\"><br>Development of mold<\/h2>\n\n\n\n<p><strong>Mold spores<\/strong> are a natural component that is permanently present in the air and usually adhere to dust particles. Under certain conditions, they can cause many problems and, for example, massively infest walls, floors, wood and other building components. The typical musty smell of mold is often noticeable in the room air when there is a large infestation. <a href=\"https:\/\/blog.gsa-messgeraete.de\/en\/testing-mold-infestation-clarifying-health-risks\/\">Molds<\/a> grow in a circular pattern, with their spores developing into a substrate of so-called filamentous structures (mycelium) up to the tips, forming circular mold growths. These feed on fats, proteins and carbohydrates as well as other organic molecules. These are found, for example, <em>in wall paints, fabrics, wood and other materials<\/em>.<\/p>\n\n\n\n<p>In the event of mold infestation, the <em>building fabric becomes too damp<\/em>. This formation may be due to the <em>nature of the building components<\/em> or the <em>behavior of the occupant<\/em>, who does not ventilate their living space properly. This is often known to be the most common cause of mold growth.  <\/p>\n\n\n\n<p>Mold can develop in old buildings as well as in new buildings and after renovations if <em>too much moisture with heat is deposited on the cool wall surfaces and condenses<\/em>. A relative humidity of around 70% on the surface of the material is sufficient to provide the right conditions for this to occur. <em>Condensation<\/em> generally settles on the coldest parts of the building fabric. Causes for the formation of dew or condensation are too <em>high relative room humidity<\/em> or too <em>cold room air or surface temperatures<\/em>. Mold often forms on wall corners and window frames.      <\/p>\n\n\n\n<p><br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Mold after renovation<\/h2>\n\n\n\n<p>After renovation work on old buildings, undesirable mold growth often occurs, as the <em>insulation<\/em> can <em>prevent the necessary air exchange<\/em>, especially with new insulation. Damage with mold growth can occur if dew points have not been properly calculated or the work has not been carried out professionally. Mold often develops in these areas, especially in the <em>corners of rooms<\/em> and on <em>window frames<\/em> and <em>areas<\/em>.<\/p>\n\n\n\n<p><br><\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Complete renovation of old buildings &#8211; causes of mold growth  <\/strong><\/h4>\n\n\n\n<p>The <em>most common cause of mold growth<\/em> is the impermeable, i.e. vapor diffusion-proof, old paint on the fa\u00e7ade, which has not been removed and therefore the moisture developing inside can no longer escape and diffuse to the outside.  <\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><br><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Insulation in window areas and walls &#8211; causes of mold growth<\/strong><\/h4>\n\n\n\n<p>A <em>common cause of mold growth on adjacent components such as windows and walls<\/em> is the <em>temperature difference<\/em> between the walls heated by insulation and the window surfaces, which remain cool. This creates a <em>thermal bridge<\/em> where adjacent components meet directly and have different thermal resistance values. With tightly sealed windows and insulation, more ventilation is required to reduce the accumulation of room humidity.  <\/p>\n\n\n\n<p>With all forms of mold growth, proper ventilation is necessary to reduce the high humidity and bring it back down to a low level and keep it there.<\/p>\n\n\n\n<p><br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Health risks due to mold  <\/h2>\n\n\n\n<p><\/p>\n\n\n\n<p><em>Irritation of the respiratory tract<\/em> and <em>eyes<\/em> as well as <em>allergic reactions<\/em> occur most frequently from molds. Molds can also lead to <em>infections<\/em> and <em>poisoning<\/em>. Elderly people, children and people with chronic pre-existing conditions are particularly at risk from contact with mold spores.<\/p>\n\n\n\n<p>To date, it has not been clarified at what concentration the molds can have negative health effects. The <em>&#8220;precautionary principle&#8221;<\/em> therefore applies because molds are a hygiene problem. They should be removed before they can cause illness. A professional procedure, for example, is to <em>measure mold accurately using suitable measuring devices<\/em> to identify areas of <em>mold spores<\/em>.    <\/p>\n\n\n\n<p><br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Prevention against mold<\/h2>\n\n\n\n<p>In general, correct <em>heating<\/em> and <em>correct ventilation<\/em> counteract the spread of mold. Proper ventilation includes <em>airing<\/em> rooms several times a day, especially in heavily insulated buildings. In addition, too much<em> moisture, such as over 70% humidity<\/em>, especially in areas such as the kitchen and bathroom, should be removed regularly. If the actual causes of mold infestation remain unrecognized &#8211; renewed infestation can be expected. In addition to proper ventilation, heating is also important to prevent the interior from cooling down too much and to prevent mold from spreading due to too much humid air.    <\/p>\n\n\n\n<p><br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Treating mold infestation  <\/h2>\n\n\n\n<p>It is important to note that spores should not be stirred up by vacuum cleaners or sweepers when removing small amounts of mold, as these can then be inhaled. When using so-called chemical &#8220;clubs&#8221; such as <em>mold removers<\/em>, <em>gloves<\/em> should be used and handled with care, as the chemical substances can damage the respiratory tract. Another <em>alternative is high-proof, 70% &#8211; 80% alcohol<\/em> for the treatment of moldy surfaces. <em>Gloves<\/em> should also be worn here. In many cases, mold removal must be carried out by specialist companies with the appropriate training, such as painting and restoration companies.     <\/p>\n\n\n\n<p><br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Measuring mold with GSA measuring devices SG5200<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>GSA measuring devices SG5200 for mold measurement<\/strong><\/h3>\n\n\n\n<p>With the <strong>GSA measuring devices <\/strong><a href=\"https:\/\/www.gsa-messgeraete.de\/SG5200-SG-5200-sampler-battery-battery-unit-silicone-tube-guide-540g\"><strong>SG5200<\/strong> <\/a>can also be used to measure the invisible spread of mold. This measuring device can be used for <em>both mobile and stationary <\/em>applications. In addition to measuring mold, it is also suitable for sampling dust fractions such as A-dust and E-dust, gases, fumes and for fibre measurements. The <a href=\"https:\/\/www.gsa-messgeraete.de\/SG5200-SG-5200-sampler-battery-battery-unit-silicone-tube-guide-540g\"><strong>SG5200<\/strong><\/a>   <strong> <\/strong>is easy <strong>to use<\/strong> and ideal for <strong>measuring mold<\/strong> in living areas and workplaces.  <\/p>\n\n\n\n<p><br><\/p>\n\n\n\n<p><strong>Sources:<\/strong><\/p>\n\n\n\n<p>Image source: 123rf.com \u00a9 janadjana, image no. 195195975<\/p>\n\n\n\n<p>www.aerzteblatt.de\/archiv\/195381\/Schimmelpilzexposition-im-Innenraum-Leitliniengerechte-Diagnosepfadex<\/p>\n\n\n\n<p>www.effizienzhaus-online.de\/schimmel-an-wand-das-koennen-sie-dagegen-tun\/<\/p>\n\n\n\n<p>www.effizienzhaus-online.de\/schimmel-entfernen-so-gehts-richtig\/<\/p>\n\n\n\n<p>www.energie-experten.org\/bauen-und-sanieren\/altbausanierung\/schimmelsanierung<\/p>\n\n\n\n<p>www.haus.de\/smart-home\/schimmel-vermeiden-die-wichtigsten-massnahmen-22816<\/p>\n\n\n\n<p>www.hausjournal.net\/schimmel-nach-sanierung<\/p>\n\n\n\n<p>www.umweltbundesamt.de\/themen\/gesundheit\/umwelteinfluesse-auf-den-menschen\/schimmel#wie-kann-man-schimmel-in-der-wohnung-vorbeugen<\/p>\n\n\n\n<p>www.umweltbundesamt.de\/themen\/gesundheit\/umwelteinfluesse-auf-den-menschen\/schimmel\/haeufige-fragen-bei-schimmelbefall#woran-erkenne-ich-einen-guten-sachverstandigen-fur-die-probenahme-und-die-bewertung-von-biologischen-schadstoffen-und-schimmel-in-innenraumen<\/p>\n\n\n\n<p>www.umweltbundesamt.de\/themen\/gesundheit\/umwelteinfluesse-auf-den-menschen\/schimmel\/haeufige-fragen-bei-schimmelbefall<\/p>\n\n\n\n<p>www.de.wikipedia.org\/wiki\/Schimmelpilz_in_Geb\u00e4uden<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Mold is often found after renovation work and can pose a health risk. Depending on the mold infestation and health sensitivity, allergic reactions or infections can be triggered. The formation should therefore be treated professionally without delay. In order to localize the spread and concentration, it is advisable to take samples with the GSA measuring &#8230; <a title=\"Measuring mold after renovations\" class=\"read-more\" href=\"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/\" aria-label=\"Read more about Measuring mold after renovations\">Read more<\/a><\/p>\n","protected":false},"author":3,"featured_media":14842,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"footnotes":""},"categories":[1089,1074],"tags":[1229,1227,1228,1226,1225,1224],"class_list":["post-10729","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-measuring-devices","category-pollutants","tag-gsa-measuring-devices-sg5200","tag-measure-mold","tag-measure-mold-infestation","tag-mold","tag-moulds","tag-sg5200-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Measuring mold after renovations - blog.gsa-messgeraete.de<\/title>\n<meta name=\"description\" content=\"Precisely measure mold with GSA measuring device SG5200 to determine possible dangerous infestation of mold spores in rooms.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Measuring mold after renovations - blog.gsa-messgeraete.de\" \/>\n<meta property=\"og:description\" content=\"Precisely measure mold with GSA measuring device SG5200 to determine possible dangerous infestation of mold spores in rooms.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/\" \/>\n<meta property=\"og:site_name\" content=\"blog.gsa-messgeraete.de\" \/>\n<meta property=\"article:published_time\" content=\"2023-11-02T11:06:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-05T12:26:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.gsa-messgeraete.de\/wp-content\/uploads\/2023\/11\/Mould-window-area.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Cornelia Umland\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@UmlandC\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Cornelia Umland\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/measuring-mold-after-renovations\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/measuring-mold-after-renovations\\\/\"},\"author\":{\"name\":\"Cornelia Umland\",\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/#\\\/schema\\\/person\\\/66e89e6575b5aa6008b4ea0acc5d38ed\"},\"headline\":\"Measuring mold after renovations\",\"datePublished\":\"2023-11-02T11:06:00+00:00\",\"dateModified\":\"2025-12-05T12:26:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/measuring-mold-after-renovations\\\/\"},\"wordCount\":996,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/measuring-mold-after-renovations\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/Mould-window-area.jpg\",\"keywords\":[\"GSA measuring devices SG5200\",\"Measure mold\",\"Measure mold infestation\",\"Mold\",\"moulds\",\"SG5200\"],\"articleSection\":[\"Measuring devices\",\"Pollutants\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/measuring-mold-after-renovations\\\/\",\"url\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/measuring-mold-after-renovations\\\/\",\"name\":\"Measuring mold after renovations - blog.gsa-messgeraete.de\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/measuring-mold-after-renovations\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/measuring-mold-after-renovations\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/Mould-window-area.jpg\",\"datePublished\":\"2023-11-02T11:06:00+00:00\",\"dateModified\":\"2025-12-05T12:26:58+00:00\",\"description\":\"Precisely measure mold with GSA measuring device SG5200 to determine possible dangerous infestation of mold spores in rooms.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/measuring-mold-after-renovations\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/measuring-mold-after-renovations\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/measuring-mold-after-renovations\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/Mould-window-area.jpg\",\"contentUrl\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/Mould-window-area.jpg\",\"width\":600,\"height\":400,\"caption\":\"Mould around windows\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/measuring-mold-after-renovations\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Measuring mold after renovations\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/\",\"name\":\"blog.gsa-messgeraete.de\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/#organization\",\"name\":\"GSA Messger\u00e4tebau GmbH\",\"url\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/wp-content\\\/uploads\\\/2016\\\/12\\\/cropped-Logo-GSA-Messgeraete-1.jpg\",\"contentUrl\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/wp-content\\\/uploads\\\/2016\\\/12\\\/cropped-Logo-GSA-Messgeraete-1.jpg\",\"width\":350,\"height\":164,\"caption\":\"GSA Messger\u00e4tebau GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/#\\\/schema\\\/person\\\/66e89e6575b5aa6008b4ea0acc5d38ed\",\"name\":\"Cornelia Umland\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/311de0177214f59652729d2b4d5d895fe80bb802ddc18b84ebfe9a2c8edeceb9?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/311de0177214f59652729d2b4d5d895fe80bb802ddc18b84ebfe9a2c8edeceb9?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/311de0177214f59652729d2b4d5d895fe80bb802ddc18b84ebfe9a2c8edeceb9?s=96&d=mm&r=g\",\"caption\":\"Cornelia Umland\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/UmlandC\"],\"url\":\"https:\\\/\\\/blog.gsa-messgeraete.de\\\/en\\\/author\\\/cn-umland\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Measuring mold after renovations - blog.gsa-messgeraete.de","description":"Precisely measure mold with GSA measuring device SG5200 to determine possible dangerous infestation of mold spores in rooms.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/","og_locale":"en_US","og_type":"article","og_title":"Measuring mold after renovations - blog.gsa-messgeraete.de","og_description":"Precisely measure mold with GSA measuring device SG5200 to determine possible dangerous infestation of mold spores in rooms.","og_url":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/","og_site_name":"blog.gsa-messgeraete.de","article_published_time":"2023-11-02T11:06:00+00:00","article_modified_time":"2025-12-05T12:26:58+00:00","og_image":[{"width":600,"height":400,"url":"https:\/\/blog.gsa-messgeraete.de\/wp-content\/uploads\/2023\/11\/Mould-window-area.jpg","type":"image\/jpeg"}],"author":"Cornelia Umland","twitter_card":"summary_large_image","twitter_creator":"@UmlandC","twitter_misc":{"Written by":"Cornelia Umland","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/#article","isPartOf":{"@id":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/"},"author":{"name":"Cornelia Umland","@id":"https:\/\/blog.gsa-messgeraete.de\/en\/#\/schema\/person\/66e89e6575b5aa6008b4ea0acc5d38ed"},"headline":"Measuring mold after renovations","datePublished":"2023-11-02T11:06:00+00:00","dateModified":"2025-12-05T12:26:58+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/"},"wordCount":996,"publisher":{"@id":"https:\/\/blog.gsa-messgeraete.de\/en\/#organization"},"image":{"@id":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.gsa-messgeraete.de\/wp-content\/uploads\/2023\/11\/Mould-window-area.jpg","keywords":["GSA measuring devices SG5200","Measure mold","Measure mold infestation","Mold","moulds","SG5200"],"articleSection":["Measuring devices","Pollutants"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/","url":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/","name":"Measuring mold after renovations - blog.gsa-messgeraete.de","isPartOf":{"@id":"https:\/\/blog.gsa-messgeraete.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/#primaryimage"},"image":{"@id":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.gsa-messgeraete.de\/wp-content\/uploads\/2023\/11\/Mould-window-area.jpg","datePublished":"2023-11-02T11:06:00+00:00","dateModified":"2025-12-05T12:26:58+00:00","description":"Precisely measure mold with GSA measuring device SG5200 to determine possible dangerous infestation of mold spores in rooms.","breadcrumb":{"@id":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/#primaryimage","url":"https:\/\/blog.gsa-messgeraete.de\/wp-content\/uploads\/2023\/11\/Mould-window-area.jpg","contentUrl":"https:\/\/blog.gsa-messgeraete.de\/wp-content\/uploads\/2023\/11\/Mould-window-area.jpg","width":600,"height":400,"caption":"Mould around windows"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.gsa-messgeraete.de\/en\/measuring-mold-after-renovations\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/blog.gsa-messgeraete.de\/en\/"},{"@type":"ListItem","position":2,"name":"Measuring mold after renovations"}]},{"@type":"WebSite","@id":"https:\/\/blog.gsa-messgeraete.de\/en\/#website","url":"https:\/\/blog.gsa-messgeraete.de\/en\/","name":"blog.gsa-messgeraete.de","description":"","publisher":{"@id":"https:\/\/blog.gsa-messgeraete.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.gsa-messgeraete.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.gsa-messgeraete.de\/en\/#organization","name":"GSA Messger\u00e4tebau GmbH","url":"https:\/\/blog.gsa-messgeraete.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.gsa-messgeraete.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/blog.gsa-messgeraete.de\/wp-content\/uploads\/2016\/12\/cropped-Logo-GSA-Messgeraete-1.jpg","contentUrl":"https:\/\/blog.gsa-messgeraete.de\/wp-content\/uploads\/2016\/12\/cropped-Logo-GSA-Messgeraete-1.jpg","width":350,"height":164,"caption":"GSA Messger\u00e4tebau GmbH"},"image":{"@id":"https:\/\/blog.gsa-messgeraete.de\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/blog.gsa-messgeraete.de\/en\/#\/schema\/person\/66e89e6575b5aa6008b4ea0acc5d38ed","name":"Cornelia Umland","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/311de0177214f59652729d2b4d5d895fe80bb802ddc18b84ebfe9a2c8edeceb9?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/311de0177214f59652729d2b4d5d895fe80bb802ddc18b84ebfe9a2c8edeceb9?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/311de0177214f59652729d2b4d5d895fe80bb802ddc18b84ebfe9a2c8edeceb9?s=96&d=mm&r=g","caption":"Cornelia Umland"},"sameAs":["https:\/\/x.com\/UmlandC"],"url":"https:\/\/blog.gsa-messgeraete.de\/en\/author\/cn-umland\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.gsa-messgeraete.de\/en\/wp-json\/wp\/v2\/posts\/10729","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.gsa-messgeraete.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.gsa-messgeraete.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.gsa-messgeraete.de\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.gsa-messgeraete.de\/en\/wp-json\/wp\/v2\/comments?post=10729"}],"version-history":[{"count":5,"href":"https:\/\/blog.gsa-messgeraete.de\/en\/wp-json\/wp\/v2\/posts\/10729\/revisions"}],"predecessor-version":[{"id":12218,"href":"https:\/\/blog.gsa-messgeraete.de\/en\/wp-json\/wp\/v2\/posts\/10729\/revisions\/12218"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.gsa-messgeraete.de\/en\/wp-json\/wp\/v2\/media\/14842"}],"wp:attachment":[{"href":"https:\/\/blog.gsa-messgeraete.de\/en\/wp-json\/wp\/v2\/media?parent=10729"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.gsa-messgeraete.de\/en\/wp-json\/wp\/v2\/categories?post=10729"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.gsa-messgeraete.de\/en\/wp-json\/wp\/v2\/tags?post=10729"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}